Engineering Geological Mapping of Gombe and environs
Thirty-seven (37) bulk samples taken from a depth of 1.5 meters were analyzed for the determination of Atterberg Limits, Linear Shrinkage, Grain Size Distribution, compaction, and California Bearing Ratio (CBR).\r\n\r\nSixteen (16) borings were made to a depth of 10 meters or to refusal. Standard Penetration Test (SPT) was carried out at every 1.5 meter depth interval and undisturbed samples were collected at the same depth or change of material for Triaxial Compression Test, Grain Size Distribution analysis, and Consolidation. All boreholes stopped at between 1.1m and 5.3 m except borehole 16, cell 056 at NYSC Zonal Office, which went to a maximum depth of 10 meters. \r\n\r\nTen (10) Dynamic Cone Penetrometer (DCP) tests were carried out using a 25mm thin walled pipe with 600 cone. Due to the fine grained nature of the dominantly clayey material, particle size distribution analysis by hydrometer method was employed.\r\n\r\nResults of field and laboratory tests reveal that the entire area on the average is overlain by a 2.5m thick sand, silt, and clay, with spot clay deposits notably at cells 056 (NYSC Zonal office) and 047 (Railway quarters). Soils of Gombe can be classified into nine groups, A-3, A-4, A-5, A-6, A-7, A-1-b, A-2-4, A-2-6, and A-2-7. Of the 37 samples analyzed, 18 are sands and hence non-plastic, 2 are silts and plotted below the A-line on the plasticity chart, while17 others are clays and plotted above the A-line.\r\nResults of SPT tests at cell 001 to 060 gave blow count (N) values of between 2 and 100 with calculated corrected N-values (N?) of between 2 and 58, at 0.5m, 1.5m, 3.0m, with maximum depth of 10m at NYSC Zonal Office. Apart from the boring at NYSC Zonal office, all borings terminated at between 1.1m to 5.3m.\r\nFrom the bulk samples recovered at 1.5m depth, bearing capacity computations based on Triaxial Compression test gave values between 277kN/m2 and 2545 kN/m2. \r\nConsolidation test results show that the materials are of medium to high compressibility. About 90% consolidation occurred within 40-120 metres, indicating secondary settlement upon application of load. The 24-hour soaked California Bearing Ratio (CBR) values between 5.1% and 11.2% shows the materials are good to be used for road subgrade. Values of maximum Dry Density (MDD) ranging between 1.09Mg/m3 and 2.17Mg/m3 with optimum moisture content (OMC) ranging from 9.5% to 19.8% were recorded. Linear shrinkage test shows low shrinkage for the sandy material, and shrinkage of up to 14% for the dominantly clayey materials. \r\n\r\nCivil constructions in Gombe require strict adherence to building standards and the findings of this work in the light of the thick clay that underlies most part of the state capital. This can go a long way in reducing incidence of multiple cracked buildings that are scattered all over the area. \r\n
Simple
- Date (Publication)
- 2008
- Presentation form
- Digital document
- Status
- Completed
- Keywords
-
-
Soil Strength, Soil Permeability, Soil Type, Slope Stability, Landform, Building Collapse
-
- Other constraints
-
Internal only
- Denominator
- 50000
- Language
- English
- Topic category
-
- Description
-
Nigeria, Gombe State, Gombe
- Reference system identifier
- 4326
- Distribution format
-
-
.doc
()
-
.doc
()
- Name of the resource
-
Engineering Geological Mapping of Gombe and environs
- Description
-
Thirty-seven (37) bulk samples taken from a depth of 1.5 meters were analyzed for the determination of Atterberg Limits, Linear Shrinkage, Grain Size Distribution, compaction, and California Bearing Ratio (CBR).\r\n\r\nSixteen (16) borings were made to a depth of 10 meters or to refusal. Standard Penetration Test (SPT) was carried out at every 1.5 meter depth interval and undisturbed samples were collected at the same depth or change of material for Triaxial Compression Test, Grain Size Distribution analysis, and Consolidation. All boreholes stopped at between 1.1m and 5.3 m except borehole 16, cell 056 at NYSC Zonal Office, which went to a maximum depth of 10 meters. \r\n\r\nTen (10) Dynamic Cone Penetrometer (DCP) tests were carried out using a 25mm thin walled pipe with 600 cone. Due to the fine grained nature of the dominantly clayey material, particle size distribution analysis by hydrometer method was employed.\r\n\r\nResults of field and laboratory tests reveal that the entire area on the average is overlain by a 2.5m thick sand, silt, and clay, with spot clay deposits notably at cells 056 (NYSC Zonal office) and 047 (Railway quarters). Soils of Gombe can be classified into nine groups, A-3, A-4, A-5, A-6, A-7, A-1-b, A-2-4, A-2-6, and A-2-7. Of the 37 samples analyzed, 18 are sands and hence non-plastic, 2 are silts and plotted below the A-line on the plasticity chart, while17 others are clays and plotted above the A-line.\r\nResults of SPT tests at cell 001 to 060 gave blow count (N) values of between 2 and 100 with calculated corrected N-values (N?) of between 2 and 58, at 0.5m, 1.5m, 3.0m, with maximum depth of 10m at NYSC Zonal Office. Apart from the boring at NYSC Zonal office, all borings terminated at between 1.1m to 5.3m.\r\nFrom the bulk samples recovered at 1.5m depth, bearing capacity computations based on Triaxial Compression test gave values between 277kN/m2 and 2545 kN/m2. \r\nConsolidation test results show that the materials are of medium to high compressibility. About 90% consolidation occurred within 40-120 metres, indicating secondary settlement upon application of load. The 24-hour soaked California Bearing Ratio (CBR) values between 5.1% and 11.2% shows the materials are good to be used for road subgrade. Values of maximum Dry Density (MDD) ranging between 1.09Mg/m3 and 2.17Mg/m3 with optimum moisture content (OMC) ranging from 9.5% to 19.8% were recorded. Linear shrinkage test shows low shrinkage for the sandy material, and shrinkage of up to 14% for the dominantly clayey materials. \r\n\r\nCivil constructions in Gombe require strict adherence to building standards and the findings of this work in the light of the thick clay that underlies most part of the state capital. This can go a long way in reducing incidence of multiple cracked buildings that are scattered all over the area. \r\n
- Function
- Download
- Statement
-
Inserted in the reports are the following maps (1:50,000): Location map, Geological map, Plasticity map, Soil Type map, Bearing Capacity map, California Bearing Ratio map, and Permeability map.